TECH SPECS-FW
SERIES TURBINE FLOW MONITOR
Technical Specifications
Display:
Large high intensity transreflective LCD 40 x 90 mm with seven 17mm digits and eleven 8mm
digits. Automatic contrast adjustment for temperature variations.
Control Panel:
Three micro-switch keys with UV - resistant polyester key pad.
Enclosure:
Polycarbonate window.
UV - resistant coated aluminum enclosure with stainless steel bolts (F012P-HA.)
Optionally available in all ABS enclosure (F012P.)
Mounting Arrangement:
Suitable for direct mount is standard. Optionally available wall mount, horizontal or vertical pipe mount
and panel mount.
Gross Dimensions:
T130 x 114 x 58 mm (5.1’ x 4.5” x 2.3” L x H x D.) Panel cut-out requirements (115 x 96 mm.)
Operating Temperatures:
T-30OC to +80OC (-20OF to +178OF.)
Battery:
Lithium-lifespan dependent upon settings; Average life up to seven years.
Configuration:
Performed at SET-UP level. Each function displayed in understandable texts. All settings
programmable; NO mechanical DIP-switches.
Password:
SET-UP level password protected.
Data Protection:
EPROM backup of all settings. Backup accumulated total every 1 minute. Data retention
10 years.
Selection Main Functions:
Total or Flow rate will be displayed with 17mm digits.
Approvals and Certifications:
CSA approvals available where necessary.
Intrinsically safe design;
F012P - ABS IP65 / NEMA 4
F012P-HA - IP 67 / NEMA 4
Directory of Available Models
FW - F012P Standard Unit:
Incorporates all main features and basic functions listed above, in an ABS enclosure.
FW - F012P-HA Standard Unit with Aluminum Enclosure:
Incorporates all main features and basic functions listed above but with Aluminum Enclosure.
All Turbines, Inc. Monitors are equipped with direct mounting fitting permitting installation on standard
turbine flow meter hub and mag pickup assembly.
For remote mount installation, extension cables (wiring harness) are optionally available.
Suitable preamplifiers are optionally available if required for extensive remote cabling.
Units incorporating broader feature set including batch controllers, modbus, and dual input capability
are also available. Contact your Turbines, Inc. authorized distributor or representative for more
information.
(c) 2005 - 2007 Turbines, Inc. - all rights
reserved.