Please click items of interest to access the information: 








 

T U R B I N E S ,   I N C .
PO Box 933
Highway 283 North
Altus, Oklahoma, 73522  USA
Phone:
1-800-809-1387
Fax: 1-580-477-3071
e-mail: karen@turbinesincorporated.com

(c) 2005-2007Turbines, Inc. all rights reserved.

Webmaster: dezi@primaryflowsignal.com

 

 

 

TECH SPECS-FW SERIES TURBINE FLOW MONITOR

Technical Specifications
Display:
Large high intensity transreflective LCD 40 x 90 mm with seven 17mm digits and eleven 8mm digits. Automatic contrast adjustment for temperature variations.
Control Panel:
Three micro-switch keys with UV - resistant polyester key pad.
Enclosure:
Polycarbonate window.
UV - resistant coated aluminum enclosure with stainless steel bolts (F012P-HA.)
Optionally available in all ABS enclosure (F012P.)
Mounting Arrangement:
Suitable for direct mount is standard. Optionally available wall mount, horizontal or vertical pipe mount and panel mount.
Gross Dimensions:
T130 x 114 x 58 mm (5.1’ x 4.5” x 2.3” L x H x D.) Panel cut-out requirements (115 x 96 mm.)
Operating Temperatures:
T-30OC to +80OC (-20OF to +178OF.)
Battery:
Lithium-lifespan dependent upon settings; Average life up to seven years.
Configuration:
Performed at SET-UP level. Each function displayed in understandable texts. All settings programmable; NO mechanical DIP-switches.
Password:
SET-UP level password protected.
Data Protection:
EPROM backup of all settings. Backup accumulated total every 1 minute. Data retention 10 years. 
Selection Main Functions:
Total or Flow rate will be displayed with 17mm digits.
Approvals and Certifications:
CSA approvals available where necessary.
Intrinsically safe design;
F012P - ABS IP65 / NEMA 4
F012P-HA - IP 67 / NEMA 4


Directory of Available Models


FW - F012P Standard Unit:
Incorporates all main features and basic functions listed above, in an ABS enclosure.
FW - F012P-HA Standard Unit with Aluminum Enclosure:
Incorporates all main features and basic functions listed above but with Aluminum Enclosure.

All Turbines, Inc. Monitors are equipped with direct mounting fitting permitting installation on standard
turbine flow meter hub and mag pickup assembly.

For remote mount installation, extension cables (wiring harness) are optionally available.

Suitable preamplifiers are optionally available if required for extensive remote cabling.

Units incorporating broader feature set including batch controllers, modbus, and dual input capability are also available. Contact your Turbines, Inc. authorized distributor or representative for more information.

 

(c) 2005 - 2007 Turbines, Inc. - all rights reserved.
This page was last updated:
Tuesday, December 06, 2005